Specification
MODEL | MDR-100-12 | MDR-100-24 | MDR-100-48 | |
Output | DC voltage | 12V | 24V | 48V |
Rated current | 7.5A | 4A | 2A | |
Rated power | 90W | 96W | 96W | |
Ripple&noise | <120mW | <150mV | <200mV | |
Voltage tolerance | ±1% | ±1% | ±1% | |
DC voltage ADJ. range | ±10% | |||
Load regulation | ±1% | ±1% | ±1% | |
Linear adjustment rate | ±1% | |||
Input | Voltage range | 85-264VAC 47Hz~63Hz(120VDC~370VDC) | ||
Efficiency | >83% | >86% | >87% | |
Power factor | PF>0.95/230VAC PF≥0.98/115VAC (full load) | |||
AC current | <1.8A 110VAC <1A 220VAC | |||
Inrush current | 110VAC 35A, 220VAC 70A | |||
Setup, rise, hold up time | 1000ms、30ms、25ms:110VAC 500ms、30ms、120ms:220VAC | |||
Protection | Overload | Rated output power 105%-150%; Protection mode: cutoff output,auto-recovery after fault condition is removed | ||
Over voltage | output voltage >135%, cutoff output; auto-recovery after fault condition is removed | |||
Over temperature | ≥85℃,cutoff output;auto-recovery after temperature become normal | |||
Environment | Working temp, humidity | -20℃~+70℃;20%~90RH | ||
Storage temp, humidity | -40℃~+85℃;10%~95RH | |||
Safety | Withstand voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC for 1 minute | ||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ | |||
Others | Dimension | 55*90*100mm | ||
Weight | 420/450g |